When placed in simulation mode, the relay suspends reading actual AC inputs, generates samples to represent the programmed phasors, and loads these samples into the memory to be processed by the relay.The footprints of both the device physical size and the lifecycle environmental impact have been minimized using state-of-the-art design, component, and process selection.
Agile solutions from GE are ideal for new-build and retrofit alike. The IEDs are suitable for a wide variety of applications in solidly-earthed, resistance-earthed and Petersen coil systems. Design attention has ensured that performance, sensitivity, customization and flexibility are delivered in a way that minimizes configuration and commissioning effort. Areva Micom S1 Software Software With FewThe devices are configured in software with few order code variants, providing standardization that reduces the risk of mis-ordering, enabling easy stocking and reducing spares holding inventory. Default applications are pre-loaded and a simple configuration column readies the product for application from a single touchpoint. Overall, the need to navigate a list of settings is reduced by approximately 80 - you only see what you need to. The relay PCBAs (printed circuit boards) have harsh environmental coating as standard, to shield from contaminants such as moisture, salt mist and atmospheric pollution, extending operational life. The scalable version has great synergy with GEs MiCOM P40 range, with settings, logic, M4 ring lugs and the PC toolsuite being common lessening training needs. Downed conductor (Hi-Z), transient ground fault and PWH wattmetric functions provide advanced functionality. The scalable application is identified as design suffix (variant) A. With Binary IO counts of up to 11i 11o, Ethernet connectivity, a sample rate of 64 samplescycle allowing for higher harmonics and THD measurement, and linked protection elements offering enhanced protection for networks with connected renewable generation, the P40 Agile Enhanced is a versatile solution for feeder protection control. The enhanced compact range is identified as design suffix (variant) E. A withdrawable design with 4, 6, and 8 case sizes for reduced space applications and MIDOS 4mm heavy-duty terminals for DC and AC terminations are central to its design. Advanced communications with support for up to two Ethernet ports, and optional redundancy protocols (RSTP or PRPHSR) offer easy integration with substation automation systems for increased situational awareness. Scalable binary IO and trip circuit supervision can coexist in a single package for demanding applications. Powerful graphical logic allows the user to customize the protection and control functions, program the opto-isolated binary inputs, relay outputs and LEDs. Integrated user function keys and tri-color programmable LEDs provide a cost-effective solution for control and annunciation. Fast overcurrent, ground fault, voltage and frequency elements form the central core of performance. Areva Micom S1 Software Plus An ExtensiveAdvanced functionality includes programmable logic and flexible configuration capabilities, plus an extensive suite of communication protocols. Switchable communication protocols are supported for ease of integration into new or existing SCADADCS systems. The hardware is standardized, providing a universal power supply, multi-range inputsoutputs, and CTVTs, to reduce order code variants and stocking spares inventories. This enables operators to pinpoint issues quickly, ensuring service reliability and availability. ![]() Areva Micom S1 Software Full Traceability OfIt also supports advanced cybersecurity features including RBAC (role-based access control) and Syslog, offering defense against threats and full traceability of user actions.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |